MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
342
IB-1501229-F
(2) Related parameters
The following are the parameters related to high-speed synchronous tapping function.
[1] NC parameter
High-speed synchronous tapping function is an option. Check the machine specifications when adjusting the
parameters.
【
#1281(PR)
】
ext17
bit 5 : High-speed synchronous tapping valid
Select whether to enable the high-speed synchronous tapping.
0: Disable
1: Enable
【
#3013-3016
】
stap1 - stap4 Synchronous tapping 1st step rotation speed
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step
acceleration/deceleration control when gears from 00 to 11 are selected.
---Setting range---
0 to 99999 (r/min)
【
#3017-3020
】
stapt1 - stapt4 Synchronous tapping 1st step acceleration/deceleration time
constant
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gears from 00 to 11 are selected. (Linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
【
#3037-3040
】
taps21 - taps24 Synchronous tapping 2nd step rotation speed
Set the speed which switches from 2nd step to 3rd step in synchronous tapping multi-step
acceleration/deceleration control when gears from 00 to 11 are selected.
---Setting range---
0 to 99999 (r/min)
【
#3041-3044
】
tapt21 - tapt24 Synchronous tapping 2nd step acceleration/deceleration time
constant
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gears from 00 to 11 are selected.
---Setting range---
1 to 5000 (ms)
【
#3001-3004
】
slimt1 - slimt4 Limit rotation speed
Set the spindle rotation speeds for maximum motor speed when gears from 00 to 11 are selected.
Set the spindle rotation speed for the S analog output=10V during analog spindle control.
---Setting range---
0 to 99999 (r/min)
【
#3045-3048
】
tapt31 - tapt34 Synchronous tapping 3rd step acceleration/deceleration time
constant
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gears from 00 to 11 are selected.
---Setting range---
1 to 5000 (ms)
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......