MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
344
IB-1501229-F
【
#2329
】
SV129 Kwf Synchronous control feed forward filter frequency
Set the acceleration rate feed forward filter frequency in high-speed synchronous tapping control.
The standard setting is "600".
---Setting range---
0 to 32767 (rad/s)
【
#2444(PR)
】
SV244 DUNIT Communication interpolation unit for communication among
drive units
Set the communication interpolation unit among drive units in high-speed synchronous tapping
control. When set to "0", it will be regarded as 20 (0.05
μ
m) is set.
(Note) This is enabled after turning ON the NC power supply again.
---Setting range---
0 to 2000 (1/
μ
m)
[Spindle]
【
#13226
】
SP226 SFNC6 Spindle function 6
Select the spindle function.
bit 3 : dd2
0: Normal setting
1: High-speed synchronous tapping function valid
(Note) The bits that are not explained here must be set to "0".
【
#13228
】
SP228 SFNC8 Spindle function 8
Select the spindle function.
bit 0-2 : lmd
Select the load display
000: Normal
001: Load display effective motor current
010: Load display motor output effective value
011: Load display high cycle
100: Load display high-cycle motor output effective value
101: Setting prohibited
110: Torque current command
111: Torque current FB
(Note 1) The bits that are not explained here must be set to "0".
(Note 2) Do not turn ON the NC power supply with the setting of SP228 bit0-2=110,111.
The initial parameter error alarm 37 is detected.
【
#13244(PR)
】
SP244 DUNIT Communication interpolation unit for communication among
drive units
Set the communication interpolation unit among drive units in high-speed synchronous tapping
control. When set to "0", it will be regarded as 20 (0.05
μ
m) is set.
(Note) This is enabled after turning ON the NC power supply again.
---Setting range---
0 to 2000 (1/
μ
m)
(Note 1) When adjusting high-speed synchronous tapping, SV032: Torque offset and SV037: Load inertia scale need to be
set.
(Note 2) The following are the parameters for adjusting. When turning ON the NC power supply again with these parameters
set, an initial parameter error alarm 37 occurs.
- Machine error compensation amount disable setting SV113 bit7 = 1
- Load display selection SP228 bit0-2 = 110, 111
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......