MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
372
IB-1501229-F
bitB. In minimum excitation rate 2 selection (PY2)
[1] When PY2=1 is set, the minimum excitation rate 2 (SP015) is being selected.
[2] When PY2=0 is set, the minimum excitation rate 1(SP014) is being selected.
bitC. In speed gain set 2 selection (VG2)
[1] When VG2=1 is set, the gain parameter (SP008/SP009/SP010) used in the speed loop isbeing selected.
[2] When VG2=0 is set, the gain parameter (SP005/SP006/SP007) used in the speed loop isbeing selected.
bitD. Zero point re-detection complete
If the zero point re-detection is completed after the zero point re-detection request (control input5/bitD) is set
to1, ORF=1 is set. If the zero point re-detection request is set to 0, ORF=0 is set.
bitF. In 2nd in-position (INP2)
The status changes to INP2=1 when position droop exists within the in-position area set by parameter SP025
(INP2) regardless of serve ON or OFF.
(Note)
The bits other than those above are used for maintenance.
(6) Spindle control output 6
bit0. In OMR-FF control (OMRFF)
OMRFF=1 (enabled) if OMR-FF control is enabled.
bit8. In drivers communication control (DD1)
DD1=1 (enabled) if high-speed synchronous tapping control is enabled.
(Note)
The bits other than those above are used for maintenance.
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
bit
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
DD1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DD1
OMRFF
OMRFF
Name
Details
Spindle
control output 6
Details
In drivers communication control
In OMR-FF control
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
(For maintenance)
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......