MDS-E/EH Series Instruction Manual
7 Troubleshooting
382
IB-1501229-F
Dual signal error (4D)
(Note) Resetting method may be "PR" depending on the sub-number in the decimal place.
No.
Name
Sub info
Details
004D.xxx
Dual signal error
-
An error was detected in the signal related to the dual signal. The name of
the axis with an error is displayed. The number "xxx" in the decimal place in-
dicates the sub-number.
004D.xxx : Alarm number.Sub-number
Sub-No.
Name
Details
Reset
method
Axis
type
Servo
stop method
Spindle
stop method
1
Power shutoff error
Either of the STO signals entered an input
state while the STO function is disabled.
NR
Each axis Dynamic stop Coast to a stop
2
Illegal power shutoff error
Either of the STO signals entered an input
state during servo ON command or during de-
celeration and stop with the STO function en-
abled.
NR
Each axis Dynamic stop Coast to a stop
3
STO signal mismatch error Input states of two STO signals were mis-
matched while the STO function is enabled.
NR
Each axis Dynamic stop Coast to a stop
15
Safety communication:
Communication error 1
A receiving error was detected in the safety
communication.
NR
Each axis Dynamic stop Coast to a stop
16
Safety communication:
Initial communication error 1
A receiving error was detected in the initial
communication for the safety communication.
PR
Each axis Dynamic stop Coast to a stop
17
Voltage diagnosis error
A power error was detected in the safety func-
tion.
NR
Each axis Dynamic stop Coast to a stop
19
DRAM diagnosis error
A DRAM error was detected in the safety
function.
PR
Each axis Dynamic stop Coast to a stop
21
Control process error
An error was detected in the status of soft-
ware execution for the safety function.
PR
Each axis Dynamic stop Coast to a stop
23
Safety encoder:
Initial communication error 1
An error was detected in the initial communi-
cation with a safety encoder.
PR
Each axis
Initial error
Initial error
24
PCB error
A PCB error was detected in the safety func-
tion.
PR
Each axis
Initial error
Initial error
25
Synchronization error
A synchronization error was detected in the
safety function.
PR
Each axis Dynamic stop Coast to a stop
26
Flash ROM diagnosis error A Flash ROM error was detected in the safety
function.
PR
Each axis
Initial error
Initial error
33
Safety encoder:
Communication error 1
An error was detected in the communication
with a safety encoder.
PR
Each axis Dynamic stop Coast to a stop
34
Safety encoder:
Diagnosis error 1
A power supply voltage error was detected in
the safety encoder.
PR
Each axis Dynamic stop Coast to a stop
35
Safety encoder:
Diagnosis error 2
A H/W error was detected in the safety en-
coder.
PR
Each axis Dynamic stop Coast to a stop
36
Safety encoder:
Diagnosis error 3
A process error was detected in the safety en-
coder.
PR
Each axis Dynamic stop Coast to a stop
37
Safety encoder:
Diagnosis error 4
An A/D conversion error was detected in the
safety encoder.
PR
Each axis Dynamic stop Coast to a stop
39
Non-safety encoder:
Position feedback fixation
diagnosis error
The position feedback from the non-safety
encoder remains unchanged.
PR
Each axis Dynamic stop Coast to a stop
40
Safety encoder:
Thermal error
The safety encoder detected a thermal error.
PR
Each axis Dynamic stop Coast to a stop
53
Safety communication:
Transmission interval mis-
match error
An error was detected in the transmission in-
terval setting.
NR
Each axis
Initial error
Initial error
54
Safety communication:
Initial communication error 2
A receiving error was detected in the initial
communication for the safety communication.
NR
Each axis
Initial error
Initial error
55
Safety communication:
Communication error 2
A receiving error was detected in the safety
communication.
NR
Each axis Dynamic stop Coast to a stop
56
Safety parameter setting
range error
A setting error was detected in the safety pa-
rameter.
PR
Each axis
Initial error
Initial error
57
Safety parameter combina-
tion error
A combination error was detected in the safe-
ty parameter.
PR
Each axis
Initial error
Initial error
65
Register diagnosis error
A resister diagnosis error was detected in the
safety function.
PR
Each axis
Initial error
Initial error
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......