MDS-E/EH Series Instruction Manual
8 Maintenance
440
IB-1501229-F
8.3.2 Replacing the Unit Fan
(1) Replacing parts
< MDS-E Series >
< MDS-EH Series >
Servo drive unit
Spindle drive unit
Power supply unit
Type
MDS-E-
Fan type
Size
[mm]
Type
MDS-E-
Fan type
Size
[mm]
Type
MDS-E-
Fan type
Size
[mm]
V1-20
9WF0424H603
40SQ.
SP-20
9WF0424H603
40SQ.
CV-37
-
-
V1-40
SP-40
CV-75
-
-
V1-80
SP-80
CV-110
9WF0624H604
60SQ.
V1-160
SP-160
9WF0624H604
60SQ.
CV-185
V1-160W
9WF0624H604
60SQ.
SP-200
9WF0924H206
90SQ.
CV-300
9WF0924H206
90SQ.
V1-320
9WF0924H206
90SQ.
SP-240
CV-370
V1-320W
SP-320
CV-450
V2-20
9WF0424H603
40SQ.
SP-400
9WF0924H403
90SQ.
CV-550
9WF1224H105
120SQ.
V2-40
SP-640
9WF1224H105
120SQ.
V2-80
SP2-20
9WF0424H603
40SQ.
V2-160
9WF0624H604
60SQ.
SP2-40
V2-160W
9WF0924H206
90SQ.
SP2-80
9WF0624H604
60SQ.
V3-20
9WF0424H603
40SQ.
SP2-16080
V3-40
Servo drive unit
Spindle drive unit
Power supply unit
Type
MDS-EH-
Fan type
Size
[mm]
Type
MDS-EH-
Fan type
Size
[mm]
Type
MDS-EH-
Fan type
Size
[mm]
V1-10
-
-
SP-20
9WF0424H603
40SQ.
CV-37
9WF0624H604
60SQ.
V1-20
9WF0424H603
40SQ.
SP-40
CV-75
V1-40
SP-80
9WF0624H604
60SQ.
CV-110
V1-80
SP-100
9WF0924H206
90SQ.
CV-185
V1-80W
9WF0624H604
60SQ.
SP-160
CV-300
9WF0924H206
90SQ.
V1-160
9WF0924H206
90SQ.
SP-200
9WF0924H403
90SQ.
CV-370
V1-160W
SP-320
CV-450
V1-200
9WF0924H403
90SQ.
SP-480
9WF1224H105
120SQ.
CV-550
9WF1224H105
120SQ.
V2-10
-
-
SP-600
CV-750
V2-20
9WF0424H603
40SQ.
V2-40
V2-80
9WF0624H604
60SQ.
V2-80W
9WF0924H206
90SQ.
V2-160
POINT
When the drive unit of E/EH Series which uses two cooling fans is in an emergency stop or alarm,
one of fans (upper one in the case of vertical layout, or either one in the case of horizontal layout) is stopped and power-
saving operation is performed. If the suspended fan is restarted by canceling the emergency stop, it is not a problem with
the fan.
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......