MDS-E/EH Series Instruction Manual
10 Appx. 1: Cable and Connector Assembly
470
IB-1501229-F
10.2 1747464-1 Plug Connector
10.2.1 Applicable Products
10.2.2 Applicable Cable
Refer to Product Specification and Application Specification for details.
10.2.3 Related Documents
10.2.4 Assembly Procedure
Assemble the cable in the following procedure:
(1) Insert accessories to the cable.
(2) Remove the sheath of the cable jacket and core wires referring to the typical
dimensions in the right figure.
Do not damage the core wires. Retry it if the core wires are partly cut off or
damaged.
The length of mesh shield should be decided referring to the right figure and be
turned up on the outside of a jacket.
(Note)
Even when the dimensions above is applied,
product performance problem can occur depending on the wires which is used.
Be sure to contact with the sales department of the manufacturer below if you consider to adopt this
connector.
Tyco Electronics Japan G.K. http://www.te.com/en/home.html
(3) Twist a copper foil tape with conductive adhesive of width 5mm around the mesh
shield.
Cable finish outside diameter:
Φ
7.3 to 7.7
(4) Refer to Application Specification (114-5335) and crimp the contacts. After crimping,
check the state in accordance with the Specification.
Part No.
Descriptions
1674320-1
1674320-2
Encoder cable I/O kit
1674335-4
Receptacle contact
Wire conductor size
Cable jacket outside diameter
#26-22AWG
6.8 to 7.4 mm
No.
Details
108-5864
Product Specification
114-5335
Rec, Contact Application Specification
114-5338
Ground Clip Application Specification
Receptacle case assembly
Wire clamp
Wire fixed set screw
Wire rubber packing
Ground clip
Cable
14
±1
mm
16
±1
mm
4
to
5mm
1.6
to
2.0mm
1.6
to
2.0mm
Mesh shield
Far side
Near side
6mm MAX
Φ7.3
to
7.7
Copper foil tape
Receptacle contact
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......