MDS-E/EH Series Instruction Manual
11 Appx. 2: D/A Output Specifications for Drive Unit
479
IB-1501229-F
< Spindle control signal >
(Note 1) Control signal is bit output. Setting the No. of the table above to the data output (SP125, SP126), and when
the scale (SP127, SP128) is set to "0", the output is "0V" for bit 0, and "2.5V" for bit 1.
(Note 2) Refer to "Spindle control signal" for details on the spindle control signal.
Spindle control input (NC to Spindle)
Spindle control output (Spindle to NC)
No.
Details
No.
Details
16384
Spindle control input 1-0
READY ON command
16480
Spindle control output 1-0
In ready ON
16385
Spindle control input 1-1
Servo ON command
16481
Spindle control output 1-1
In servo ON
16391
Spindle control input 1-7
Alarm reset command
16487
Spindle control output 1-7
In alarm
16392
Spindle control input 1-8
Torque limit 1 selection
command
16488
Spindle control output 1-8
In torque limit 1 selection
16393
Spindle control input 1-9
Torque limit 2 selection
command
16489
Spindle control output 1-9
In torque limit 2 selection
16394
Spindle control input 1-A
Torque limit 3 selection
command
16490
Spindle control output 1-A
In torque limit 3 selection
16492
Spindle control output 1-C
In in-position
16495
Spindle control output 1-F
In warning
16496
Spindle control output 2-0
Z phase passed
16499
Spindle control output 2-3
In zero speed
16503
Spindle control output 2-7
In external emergency stop
16409
Spindle control input 2-9
Speed monitor command
valid
16505
Spindle control output 2-9
In speed monitor
16410
Spindle control input 2-A
In door closed (controller)
16506
Spindle control output 2-A
In door closed (controller)
16411
Spindle control input 2-B
In door closed (all drive units)
16507
Spindle control output 2-B
In door closed (self drive unit)
16432
Spindle control input 4-0
Spindle control mode
selection command 1
16528
Spindle control output 4-0
In spindle control mode
selection 1
16433
Spindle control input 4-1
Spindle control mode
selection command 2
16529
Spindle control output 4-1
In spindle control mode
selection 2
16434
Spindle control input 4-2
Spindle control mode
selection command 3
16530
Spindle control output 4-2
In spindle control mode
selection 3
16436
Spindle control input 4-4
Gear changeover command
16532
Spindle control output 4-4
In gear changeover
command
16437
Spindle control input 4-5
Gear selection command 1
16533
Spindle control output 4-5
In gear selection 1
16438
Spindle control input 4-6
Gear selection command 2
16534
Spindle control output 4-6
In gear selection 2
16535
Spindle control output 4-7
Magnetic pole position not
set
16445
Spindle control input 4-D
L coil selection command
16541
Spindle control output 4-D
In L coil selection
16545
Spindle control output 5-1
Speed detection
16550
Spindle control output 5-6
In coil changeover
16458
Spindle control input 5-A
Phase synchronization
suppression command
16554
Spindle control output 5-A
In phase synchronization
suppression
16459
Spindle control input 5-B
Minimum excitation rate 2
changeover request
16555
Spindle control output 5-B
In minimum excitation rate 2
selection
16460
Spindle control input 5-C
Speed gain set 2 changeover
request
16556
Spindle control output 5-C
In speed gain set 2 selection
16461
Spindle control input 5-D
Zero point re-detection
request
16557
Spindle control output 5-D
Zero point re-detection
complete
16462
Spindle control input 5-E
Increase holding power of
spindle
16558
Spindle control output 5-E
Increase holding power of
spindle completed
16559
Spindle control output 5-F
In 2nd in-position
16472
Spindle control input 6-8
Drivers communication
control request
16568
Spindle control output 6-8
In drivers communication
control
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......