MDS-E/EH Series Instruction Manual
12 Appx. 3: Protection Function
491
IB-1501229-F
(3) Parameter setting for spindle drive unit
Starts the SLS (Safely Limited Speed) function.
【
#13229
】
SP229 SFNC9 Spindle function 9
bit F : ssc SLS (Safely Limited Speed) function
0: Disable 1: Enable
The digital signal input selection is set to "1" for the drive unit connected with the door state signal.
The digital signal input selection is set to "0" for the other drive unit not connected with the signal.
bit D : rps Safely limited speed setting unit
0: Normal 1: 100°/min
Change the setting units of the specified speed signal output speed (SP030) and safely limited
speed (SP238).
【
#13227
】
SP227 SFNC7 Spindle function 7
bit F-C : dis Digital signal input selection
0: No signal
1: SLS (Safely Limited Speed) function door state signal
4: Proximity switch signal detection
Other settings: setting prohibited
Sets the safely limited speed of the machine and motor for which the SLS (Safely Limited Speed) function is
executed.
【
#13238
】
SP238 SSCFEED Safely limited speed
Set the safely limited speed at the spindle end for the SLS (Safely Limited Speed) function.
When not using, set to "0".
---Setting range---
0 to 18000 (
゜
/min)
However, when SP229/bitD is set to "1", the setting range is from -32768 to 32767 (100
゜
/min).
【
#13239
】
SP239 SSCRPM Safely limited motor speed
Set the motor's safely limited speed for the SLS (Safely Limited Speed) function.
When not using, set to "0".
---Setting range---
0 to 32767 (r/min)
(Note)
The value of the safely limited speed and safely limited motor speed must satisfy the following relation.
If this relation is not satisfied, the parameter error (37or E4) will occur. (Error parameter No. is 239.)
Checking this relation is executed when the drive unit is turned ON and parameter is changed and speed
observation mode (states when a speed observation command is turned ON) is entered.
Note that "1 (r/min)" is applied when the calculation result is "0 (r/min)"
SP238 :SSCFEED
360
X
= SP239
:SSCRPM
SP057 :GRA1
SP061 :GRB1
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......