3. I/O Parameters
3.1 Base Parameters
II - 17
3. I/O Parameters
Pressing the menu key
I/O
PARA
displays the I/O BASE PARAM screen.
There are basically two types of input/output parameters which must be set when inputting‚ outputting or
referring to data‚ or when performing tape operation. One type is the parameters related to the input/output
device. The baud rate‚ etc.‚ is set according to each device. Up to five types of input/output devices can be
registered. The other type of input/output parameters is the I/O base parameters which determine which
device is connected to which channel per input/output application.
3.1 Base Parameters
<I/O>
#
<PORT No.>
#
<DEV. No.> <DEV. NAME>
Specify the board No. to which the serial
input/output device is connected to 2.
•
Set "1" to use ch1.
•
Set "2" to use ch2.
Set the input/output device No. for
each application.
The device Nos. are 0 to 4 and
correspond to the input/output
device parameters.
The device name set in the
input/output device parameter is
also displayed for identification.
DATA IN
9001 Specify the port for inputting the data
such as machine program and
parameters.
9002 Specify the device No. that inputs
the data.
DATA OUT
9003 Specify the port for outputting the data
such as machine program and
parameters.
9004 Specify the device No. that outputs
the data.
TAPE MODE
9005 Specify the input port for running with
the tape mode.
9006 Specify the device No. to be run
with the tape mode.
MACRO
PRINT
9007 Specify the output port for the user
macro DPRINT command.
9008 Specify the device No. for the
DPRINT command.
PLC IN/OUT
9009 Specify the port for inputting/outputting
various data with PLC.
9010 Specify the device No. for the PLC
input/output.
REMOTE
PROG IN
9011 Specify the port for inputting remote
programs.
The port No. must be "2".
9012 Specify the device No. used to
input remote programs.
EXT UNIT
9013 Specify the port for communication with
an external unit.
9014 Specify the unit No. used for
communication with an external
unit
#
Item
Contents
Setup range (unit)
9015 PORT NO.
(tool ID)
Set the number of the port connected with the tool
ID. (Either ch1 or ch2 can be used.)
•
Set "1" to use ch1.
•
Set "2" to use ch2.
1/2
(M64)
9016 DEV. NO.
(tool ID)
Set the number of the input/output device to be
used.
(Any device No. can be used.)
0 to 4
(M64)
Summary of Contents for MELDAS 60 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 13: ...I EXPLANATION OF ALARMS ...
Page 14: ......
Page 95: ...II EXPLANATION OF PARAMETERS ...
Page 96: ......
Page 443: ......