5. Base Specifications Parameters
II - 26
#
Items
Details
Setting range (unit)
1037 cmdtyp Command
type
Specify the program G code series and
compensation type.
There are some items in the specifications that can
be used or cannot be used according to the value set
in this parameter.
The file structure may also change depending on the
compensation data type.
Thus‚ after changing this parameter‚ initialize the
system with #1060 SETUP.
1 to 8
1038 plcsel
Ladder
selection
Specify the PLC type.
0: User custom PLC
1: Standard
PLC
2: Exclusive PLC for
MELSEC bus link
1039 spinno Number of
spindles
Specify the existence of a spindle.
0: No spindle
1: One
spindle
2: Two
spindles
3: Three
spindles
4: Four
spindles
1040
(PR)
M_inch Constant
input (inch)
Specify the parameter unit system for the position
and length.
0: Metric system
1: Inch
system
1041
(PR)
l_inch Initial
state
(inch)
Specify the unit system for the program movement
amount when the power is turned ON or reset and for
position display. Designate an internal unit.
0: Metric
system
1: Inch
system
1042
(PR)
pcinch PLC
axis
command
(inch)
Specify the unit system for the commands to the PLC
axis.
0: Metric system
1: Inch
system
cmdtyp
G code series
Compensation type
1
System 1 (for M)
Type A (one compensation
amount for one compen-
sation number)
2
System 2 (for M)
Type B (shape and wear
amounts for one compen-
sation number)
3
System 2 (for L)
Type C (two kinds of
compensation amount of
shape and wear per
compensation No.)
4
System 3 (for L)
Same as above
5 System
4
(for special L)
Same as above
6 System
5
(for special L)
Same as above
7 System
6
(for special L)
Same as above
8
System 7
(for special L)
Same as above
Summary of Contents for MELDAS 60 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 13: ...I EXPLANATION OF ALARMS ...
Page 14: ......
Page 95: ...II EXPLANATION OF PARAMETERS ...
Page 96: ......
Page 443: ......