5. Base Specifications Parameters
II - 27
#
Items
Details
Setting range (unit)
1043 lang
Select
language
displayed
Specify the display language.
0: Japanese
display
(Standard)
1: English
display
(Standard)
2: Third language displayed (Note) (Option)
3: Fourth language displayed (Note) (Option)
11: Display in German
(Option)
12: Display in French
(Option)
13: Display in Italian
(Option)
14: Display in Spanish
(Option)
15: Display in Chinese
(Option)
(traditional Chinese)
16: Display in Korean
(Option)
17: Display in Portuguese
(Option)
18: Display in Dutch
(Option)
19: Display in Swedish
(Option)
20: Display in Hungarian
(Option)
22: Display in Chinese
(Option)
(simplified
Chinese)
23: Display in Russian
(Option)
Note: If no character package is available for a
specified language, the screen is displayed
in English.
0 to 3
11 to 22
1044
(PR)
auxno MR-J2-CT
Connections
Specify the number of MR-J2-CTs connected.
0 to 4
1045
(PR)
nskno Megatorgue
motor
connections
Specify the number of NSK megatorque motors
connected. When a value other than 0 is specified,
2nd miscellaneous function data is output as signed
binary data.
0 to 16
1049
(PR)
mmac_R Machine
maker macro
RAM-ROM
changeover
Select the memory area for the machine
manufacturer macro program.
0: SRAM area
1: FROM area
When this parameter is changed, the power must be
turned OFF and ON, and the area must be formatted.
Note: “1” cannot be set if the machine
manufacturer macro option is not valid.
0/1
Note: Selection of inch and metric unit
When set value of #1041 I_inch is changed‚ the unit of length is changed after reset.
Among parameters concerning length‚ following items are not changed automatically‚ therefore
change the set values to agree with the new unit system when the unit system is changed.