5. Base Specifications Parameters
II - 32
#
Items
Details
Setting range (unit)
1065 JOG_H
JOG
response
type
Set up an improved JOG response type.
0: Conventional specification
The system is started and stopped by signal
via ladder without reference to external input
signals.
1: Type
1
The system is started up and stopped by
external signal.
2: Type
2
The system is started up and stopped by
performing the AND operation for external
signals and those via ladder.
3: Type
3
The system is started up when signals via
ladder rise. It is stopped when external signals
and those via ladder fall.
4: Type
4
Zero point return mode: The system is started
up and stopped by signal via ladder without
reference to external input signals
(conventional specification).
Non-zero point return mode: The system is
started up and stopped by performing AND
for external signals and those via ladder
(type 2).
0 to 4
1066 JOG_HP Select
JOG
activation
(+) device
Specify the number of the device that JOG
activation signals. The device type is specified by
JOG_D in #1071. The effective range of set values
vary depending on the device type. A value outside
of the effective range is invalid if specified.
X: 0000 to 013F
(hexadecimal)
G: 0000 to 3071
M: 0000 to 5119
(decimal)
1067 JOG_HN Select
JOG
activation
(
−
) device
Specify the number of the device that inputs -JOG
activation signals. The device type is specified by
JOG_D in #1071. The effective range of set values
vary depending on the device type. A value outside
of the effective range is invalid if specified.
X: 0000 to 013F
(hexadecimal)
G: 0000 to 3071
M: 0000 to 5119
(decimal)
1068
(PR)
slavno Slave
axis
number
Specify the number of the slave axis for synchronous
control. The axis number is an NC number excluding
the spindle and PLC axis.
Two or more slave axes cannot be set up for one
master axis.
slaveno cannot be set up for a slave axis.
A dual system cannot be set up so that the
relationship between the master and slave axes
extends over a system.
0: No slave axis
1 to 4:
First to fourth
axes
1 to 14:
1st axis to 14th
axis
(For simple C axis
synchro-
nous control)