5. Base Specifications Parameters
II - 45
#
Items
Details
Setting range (unit)
1148 I_G611 Initial high
precision
The modal state when the power is turned ON is set to
the high accuracy control mode.
0: OFF
1: ON
0/1
1149 cireft
Arc
deceleration
speed
change
Specify whether to enable deceleration at the arc
entrance or exit.
0: Disable
1: Enable
0/1
1150 Fldc0
G00 feed
forward filter
This parameter is used to filter acceleration changes at
the start of rapid acceleration/deceleration. Specify the
filters in bit units.
3
0
1
2
5
4
6
7
Feed forward filter
G00/G01 separation
G00 feed forward filter
0: Common 1: Separation
bit1: 7.1 (ms)
bit2: 14.2 (ms)
bit3: 28.4 (ms)
bit4: 56.8 (ms)
bit5: 113.6 (ms)
When bits 1 to 5 are
all 0 or when two or
more of bits 1 to 5 are
1, 3.5 (ms) is
assumed.
1151 rstint
Reset initial
Specify whether to initialize (power ON state) the
modals by resetting.
0: Do not initialize modal state.
1: Initialize modal state.
0/1
1152 I_G20 Initial
command
unit
Specify whether the default mode after power-ON or
resetting, inch command or metric command mode.
0: Metric command (G21 command state)
1: Inch command (G20 command state)
Valid when reset input is made.
Related parameter: Bit 6 “Select setting and display
unit” of #1226
0/1
1153 FixbDc Hole bottom
deceleration
check
Specify whether to perform a deceleration check or
in-position check at the hole bottom in the hole drilling
cycle. This parameter is valid only for a hole drilling
cycle in which no dwell command can be issued at the
hole bottom.
0: Perform no deceleration check and in-position
check.
1: Perform a deceleration check.
2: Perform an in-position check.
0 to 2
Summary of Contents for MELDAS 60 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 13: ...I EXPLANATION OF ALARMS ...
Page 14: ......
Page 95: ...II EXPLANATION OF PARAMETERS ...
Page 96: ......
Page 443: ......