5. Base Specifications Parameters
II - 53
#
Items
Details
Setting range (unit)
(Continued from the previous page)
L system
Specify a hexadecimal
number.
1211 FHtyp
Feed hold stop
type
Specify the type of the external signal used for feed
hold.
0: Disable the external signal.
1: Enable the external signal (contact A)
2: Enable the external signal (contact B)
0 to 2
1212 FHno
Feed hold
external signal
device
Specify the number (X??) of the device used to input
the feed hold signal.
000 to 13F
(hexadecimal)
1213 proaxy
(For L
system
only)
Side 1 of
inclination
angle
Specify the length on the rectangular coordinates of
the inclined axis in the triangle made up of the
inclination angle.
±9999.999
0
Group 1 Move G modal
1
Group 2 Flat selection modal
2
Group 3 Absolute/increment command modal
3
Group 4 Barrier check modal
4
Group 5 Feed G modal
5
Group 6 Inch/metric modal
6
Group 7 Nose R compensation modal
7
8
9
Group 10 Fixed cycle return command modal
A
B
Group 12 Workpiece coordinate system modal
C
Group 13 Cut modal
D
E
F
10
Group 17 Constant surface speed control command modal
11 Group 18 Balance cut
12
13 Group 20 Spindle 2 control modal
14 Group 15 Facing turret mirror image
15
16
17
18
19
1A
1B
1C
1D
1E
1F