5. Base Specifications Parameters
II - 59
#
Items
Details
Setting range (unit)
aux07
(bit2)
Synchronous
tap R-point
in-position
check
0: Disable the synchronous tap I-point
→
R-point
in-position check.
1: Enable the synchronous tap I-point
→
R-point
in-position check.
(Applicable only to M64 D version series)
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0/1
aux07
(bit3)
Synchronous
tap in-position
check
improvement
Specify whether to enable the synchronous tap
in-position check improvement function. (Applicable
only to M64 D version series)
0: Disable
1: Enable
Related parameters:
#1223
bit 2 Synchronous tap R-point in-position check
bit 4 Synchronous tap hole bottom in-position
check
bit 5 Synchronous tap R-point in-position check 2
0/1
aux07
(bit4)
Synchronous
tap hole bottom
in-position
check
0: Disable the synchronous tap hole bottom
in-position check.
1: Enable the synchronous tap hole bottom
in-position check.
(Applicable only to M64 D version series)
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0/1
aux07
(bit5)
Synchronous
tap R-point
in-position
check 2
0: Disable synchronous tape R-point in-position
check.
1: Enable synchronous tape R-point in-position
check.
(Applicable only to M64 D version series)
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0/1
aux07
(bit6)
Cancel
synchronous
tap (,S) return
0: Retains a spindle rotation speed (, S) when
performing synchronous tap return.
1: Cancels a spindle rotation speed (, S) by return
with G80.
0/1
aux07
(bit7)
Synchronous
tap method
Specify a synchronous tap method.
0: Synchronous tap (multi-step acceleration and
deceleration and rapid return)
1: Conventional type synchronous tap
0/1
1224 aux08
(bit0)
Sampling data
output
Set the validity of the sampling data output.
0: Sampling output invalid
1: Sampling output valid
0/1