5. Base Specifications Parameters
II - 63
#
Items
Details
Setting range (unit)
aux11
(bit7)
Switch the
range of tool life
data to be input
(For M system
only)
set up the range of tool life data to be input or
compared.
0: Inputs or compares all of the data output.
1: Inputs or compares part of the data output
1) Tool life management I data to be input or
compared tool number (D), lifetime (E),
life count (F), and auxiliary data (B).
2) Tool life management II data to be input or
compared Group number (G), method
(M), life (E/F), tool number (D), and
compensation number (H)
Note: When the maintenance function data input/
output #(99) ( ) is set, all data will be input
and compared.
0/1
1228 aux12
(bit0)
Switch
coordinate
value screen
Set up this option to switch the coordinate value
screen.
0: 80-character
screen
1: 40-character
screen
0/1
aux12
(bit1)
Switch offset
and parameter
screen
Set up this option to switch the offset and parameter
screen to the parameter screen.
0: Displays the offset and parameter screen.
1: Displays the parameter screen.
0/1
aux12
(bit2)
Switch data
protection in
data
transmission
mode
Set up the range of data protection in data
transmission mode.
0: Protects both send and receive data.
1: Protects receive data only.
0/1
aux12
(bit3)
Nose R
specification
Select whether to specify the nose R compensation
by shape or wear number.
0: Specifies the nose R compensation by shape
number.
1: Specifies the nose R compensation by wear
number.
0/1
aux12
(bit4)
Select operation
error or stop
code
Specify both block cutting start interlock and cutting
start interlock as the operation error or stop code.
0: Operation
error
1: Stop
code
0/1
aux12
(bit5)
Select constant
surface speed
coordinates
Select constant surface speed coordinates.
0: Workpiece coordinate value
1: Absolute coordinate value
0/1
aux12
(bit6)
Switch relative
values
displayed
Select whether to preset the relative coordinates
with workpiece coordinate preset (G92.1) or counter
preset (G92).
0: Preset relative coordinates.
1: Do not preset relative coordinates.
0/1