5. Base Specifications Parameters
II - 64
#
Items
Details
Setting range (unit)
aux12
(bit7)
Protection with
manual value
command
Set up this option to protect a manual value
command.
0: Does not protect the manual value command
(same as before).
1: Protects the manual value command.
0/1
1229 set01
(bit0)
Subprogram
interrupt
0: Specifies the user macro interrupt of macro
type.
1: Specifies the user macro interrupt of
sub-program type.
0/1
set01
(bit1)
Accurate thread
cutting E
0: Address E specifies the number of threads per
inch for inch screw cutting.
1: Address E specifies precise reading for inch
screw cutting.
0/1
set01
(bit2)
Radius compen-
sation type B
(For M system
only)
0: When the start-up and cancel commands are
operated during radius compensation, their
blocks are not handled by intersection operation
processing; they are handled as offset vectors
in the direction vertical to that of the commands.
1: When the start-up and cancel commands are
operated during radius compensation, the
intersection operation processing of the
command block and the next block is executed.
0/1
set01
(bit2)
Nose R
compen-
sation type B
(For L system
only)
0: When the start-up and cancel commands are
operated during nose R and radius
compensation, their blocks are not handled by
intersection operation processing; they are
handled as offset vectors in the direction vertical
to that of the commands.
1: When the start-up and cancel commands are
operated during nose R and radius
compensation, the intersection operation
processing of the command block and the next
block is executed.
0/1
set01
(bit3)
Initial constant
surface speed
0: The initial state after power-ON is a constant
surface speed control cancel mode.
1: The initial state after power-ON is a constant
surface speed control mode.
0/1
set01
(bit4)
Synchronous
tap
0: Handles the G74 and G84 tap cycles as the tap
cycles with a floating tap chuck.
1: Handles the G74 and G84 tap cycles as the tap
cycles without a floating tap chuck.
0/1
set01
(bit5)
Start point alarm Select an operation when the operation start point
cannot be found while moving the next block of
G117.
0: Enables an auxiliary function after the block
has been moved.
1: Outputs an program error (P33) when the
operation start point is not found.
0/1