5. Base Specifications Parameters
II - 65
#
Items
Details
Setting range (unit)
set01
(bit6)
Grid display
selection
Select a grid type to be displayed on the servo
monitor screen during dog type reference point
return.
0: Selects the distance between dog OFF and
zero point (including a grid mask amount).
1: Selects a value given by reducing a grid mask
amount from the distance between dog OFF
and zero point.
0/1
1230 set02
(bit7)
Macro interface
input/output for
each system
0: The macro interface input/output are shared
by the systems.
1: The macro interface input/output are used
independently by the systems.
0/1
1231 set03
(bit1)
Switch graphic
coordinates
Select whether to draw graphics with the machine
coordinate value or the tool position coordinate value
(position being machined, obtained by subtracting
the tool compensation amount from machine
coordinate values) when displaying the trace
function.
0: Machine coordinate value (same as
conventional method)
1: Tool position coordinate value
The counter display and counter name are
sequenced with this.
0/1
set03
(bit2)
Switch graphic
check trace
Select whether to draw both the machine coordinate
value (tool center path) and tool position coordinate
value (program path) or draw only the coordinates
selected with switch graphic coordinates (#1231
set03/
bit1) when using the program check function.
0: Both machine coordinates and tool position
coordinates (same as conventional method)
1: Only coordinates designated with switch
graphic coordinates.
0/1
set03
(bit3)
Hold display
range
information
Select whether to hold the display range information
(drawing position and scale value) for graphic displays.
0: Hold.
1: Do not hold. (Initialize each time ... same as
conventional method)
0/1
set03
(bit4)
Switch zero
point mark
display position
Select the position for displaying the zero point mark
in the graphic display.
0: Machine coordinate zero point (same as
conventional method)
1: Workpiece coordinate zero point
0/1