5. Base Specifications Parameters
II - 67
#
Items
Details
Setting range (unit)
set09
(bit0)
External
workpiece offset
Set up this function to use the external workpiece
coordinates by shifting them to the Z axis.
0: Does not reverse the sign of external
workpiece offsets (Z shift) (same as before).
1: Reverses the sign of external workpiece
offsets (Z shift).
Note: When the sign of external workpiece offsets
(Z shift) has been reversed, do not measure
those external workpiece offsets. However,
the external workpiece offsets can be
measured by tool pre-setter.
0/1
1237
(PR)
set09
(bit1)
Switch PC I/F F
modal
The feedrate display for the special display unit is
changed.
0: Display as feed per minute.
1: Change between feed per minute and feed
per rotation according to the modal state.
0/1
set09
(bit2)
Switch PC I/F T
modal
The T command display for the special display unit
is changed. (Only L system)
0: Display tool No. (excluding low-order two
digits).
1: Display including the compensation No.
0/1
set09
(bit3)
Switch PC I/F
remaining
distance dwell
time display
The dwell time display for the special display unit is
changed.
0: Display at feedrate display position.
1: Display at remaining distance display
position.
0/1
set09
(bit4)
Switch PC I/F
execution
program
display/
comment
display
The display of the program being executed for the
special display unit is displayed.
0: Display as searched state, regardless of
operation mode.
1: If operation mode and searched program
differ, program is not displayed.
Comment is displayed for head block search.
0/1
set09
(bit5)
Switch PC I/F
modal S
This parameter is for the special display unit I/F.
0: The S command commanded last is returned.
1: When #1039 spinno is 1
The 1st spindle data is returned.
When #1039 spinno is 2
If #1199 Sselect for 2nd system is set to 1
with 2nd system setting, the 2nd spindle
data is returned.
When another command is issued, the 1st
spindle data is returned.
Note: When using constant surface speed
control (G96 modal), the actual rotation
speed command is returned.
0/1