5. Base Specifications Parameters
II - 73
#
Items
Details
Setting range (unit)
ext08
(bit4)
Tap cycle
selection
Select the tap cycle.
0: Pecking tap cycle
1: Deep hole tap cycle
0/1
ext08
(bit5)
Deep hole tap
cycle override
selection
Select whether to validate override on the pulling
operation during synchronized tapping with the
deep hole tap cycle.
0: Invalid
1: Valid
0/1
ext08
(bit6)
Switch corner
chamfering/
corner R
command
format
The corner chamfering/corner R command format is
extended.
0: Command format I (conventional format)
Issue a command with comma (,C and ,R).
1: Command format II
In addition to command format I, commands
can be issued with an address that does not
have a comma.
Corner chamfering: I/K or C, corner R: R
0/1
ext08
(bit7)
Return position
after macro
interrupt in fixed
cycle selection
Select the destination to return to after a macro
interrupt in the fixed cycle.
0: Return to block in fixed cycle.
1: Return to block after fixed cycle.
0/1
1273
(PR)
ext09
(bit0)
Switch ASIN
calculation
results range
Select the ASIN calculation results range.
0: –90° to 90°
1: 90° to 270°
0/1
ext09
(bit1)
Switch system
variable unit
Select the unit for the system variable #3002 (time
during automatic start).
0: 1ms
unit
1: 1 hour unit
0/1
ext09
(bit2)
Switch G71,
G72, G73
cutting direction
judgment
Select whether to determine the cutting direction
with the finished shape, or according to the
commanded finishing allowance and cutting
allowance when the longitudinal rough cutting cycle
(G71), face rough cutting cycle (G72) or closed loop
cutting cycle (G73) is commanded.
0: Conventional
specifications
Determined according to the finished shape
program.
1: Extended
specifications
Determined according to the finishing
allowance and cutting allowance
commanded in the program.
0/1
ext09
(bit3)
Facing turret
mirror image
coordinate value
type
Select the coordinate values of the axis for which
facing turret mirror image is valid.
0: Move axis in same direction as machine
value.
1: Move axis in direction opposite machine
value.
0/1
ext09
(bit4)
Facing turret
mirror image
valid axis
selection
Select the axis for which facing turret mirror image
is valid.
0: Fixed to 1st axis.
1: Determined according to plane selected
when facing turret mirror image is
commanded.
0/1