5. Base Specifications Parameters
II - 84
(SETUP PARAM 1. 11/15)
#
Items
Details
Setting range (unit)
1501 polyax
(For L
system
only)
Rotational
tool axis
number
Specify the number of the rotational tool axis (servo
axis) used for polygon machining (G51.2). Set 0
when not using polygon machining (spindle-servo
axis), or when using spindle-spindle polygon
machining. A value exceeding the base specification
parameter #1002 axisno cannot be specified.
This parameter is valid when the G code system is 6
or 7 (7 or 8 is set in base specification parameter
#1037 cmdtyp).
0 to controlled axis
number
1502 G0Ipfg
G1
→
G0
deceleration
check
0: Do not perform a deceleration check when the
move direction is changed from G1 to G0.
1: Perform a deceleration check when the move
direction is changed from G1 to G0.
(Applicable only to the M64 D version series)
0/1
1503 G1Ipfg
G1
→
G1
deceleration
check
0: Do not perform a deceleration check when the
move direction is changed from G1 to G1.
1: Perform a deceleration check when the move
direction is changed from G1 to G1.
(Applicable only to the M64 D version series)
0/1
1505 ckref2
Second origin
return check
Specify the trigger for a check at the specified position
in manual second original return mode.
0: Completion of spindle orientation
1: Generation of second origin return interlock
signal
0/1
1506 F1_FM
Upper limit of
F1 digit
feedrate
Specify the maximum value up to which the F1 digit
feedrate can be changed.
(Applicable only to M65 and M66)
0 to 60000 (mm/min)
1507 F1_K
F1 digit
feedrate
change
constant
Specify the constant that determines the speed
change rate per manual handle graduation in F1 digit
feedrate change mode.
(Applicable only to M65 and M66)
0 to 32767
1510 DOOR_H Shorten door
interlock II
axis stop time
Specify whether to shorten the time during which the
axis is stopped when the door is opened.
0: Use the conventional axis stop time.
1: Shorten the axis stop time.
Note: When the door interlock II signal is input via a
ladder, the conventional axis stop time is used.
0/1
1511 DOORPm Signal input
device 1 for
door interlock
II: for each
system
Specify the fixed device number (X??) for door
interlock II signal input for each system.
A device number from X01 to XFF can be specified.
Device number 000 is invalid.
Specify device number 100 when using no fixed
device number for door interlock II signal input.
Related parameter: #1154 pdoor (Door interlock II for
each system)