5. Base Specifications Parameters
II - 91
(SETUP PARAM 1. 15/15)
#
Items
Details
Setting range (unit)
1925 EtherNet
Start of service Start or stop the Ethernet communication function.
0: Stop
1: Start
0/1
1926 IP
address
IP address
Specify the NC IP address
1927 Subnet
mask
Subnet mask
Specify the subnet mask.
1928 Gateway
address
Gateway
Specify the gateway IP address.
Set these parameters
in accordance with the
network rules in the
connection
environment.
1929 Port
number
Port No.
Set the port No. for the service function.
1 to 9999
(Set 2000 when not
connected to the
Ethernet.)
1930 Host
address
Host address
Set the host's IP address.
1 to 255
1931 Host
number
Host No.
Set the host's port No.
1 to 9999
1932 FTP Retry FTP
communica-
tion retry times
Set the number of times to retry automatically when
FTP communication fails.
0 to 999
1933 FTP
Timeout
FTP
communica-
tion time-out
interval
Set the communication time-out interval (seconds)
when FTP communication automatic retry is set. If
"0" is set, "10" seconds (default value) is applied.
0 to 99
(Note) Always set #1925 to #1931 when the FCU6-EP203-1 is mounted.