Remedy
0115
RESETTING
The automatic start button was pressed
during resetting or tape rewinding.
• When rewinding the tape‚ wait for the
winding to end‚ or press the reset button
to stop the winding‚ and then press the
automatic start button.
• During resetting‚ wait for resetting to end‚
and then press the automatic start button.
0117
PLAYBACK NOT POSSIBLE
The playback switch was turned ON
during editing or full-character mode
(9-inch).
• During editing‚ cancel the function by
pressing the input or previous screen key‚
and then turn ON the playback switch.
• Set the edit screen (9-inch) to the
half-character mode‚ and then turn ON
the playback switch.
0118
Block joint turn stop during normal line
control
The turning angle at the block joint
exceeded the limit during normal line
control.
Normal line control type I
The normal line control axis turning
speed (#1523 C_feed) has not been
set.
Normal line control type II
When turning in the inside of the arc, the
parameter “#8041 C-rot. R” setting value
is larger than the arc radius.
• Check the program.
• Set the normal line control axis turning
speed. (Parameter “#1523 C_feed”)
• Set the C axis turning diameter smaller
than the arc radius, or check the setting
value of the C axis turning diameter.
(Parameter “#8041 C rot. R”)
0120
Synchronization correction mode ON
The synchronous correction mode
switch was pressed in a non-handle
mode.
• Select the handle or manual feed mode.
• Turn OFF the correction mode switch.
0121
No synchronous control option
The synchronous control system
(register R435) was set with no
synchronous control option.
• Set 0 in register R435.
0123
Computer link B
The cycle start was attempted before
resetting was completed.
The operation of the computer link B
was attempted in the 2nd part system of
the 2-part system.
• Perform the cycle start after resetting is
completed.
• Set 0 in #8109 HOST LINK, and then set
1 again before performing the cycle start.
• The operation of the computer link B
cannot be performed in the 2nd part
system of the 2-part system.
0124
Simultaneous axis movement prohibited
during inclined axis control valid
The basic axis corresponding to the
inclined axis was started simultaneously
in the manual mode while the inclined
axis control was valid.
• Turn the inclined axis and basic axis start
OFF for both axes. (This also applied for
manual/automatic simultaneous start.)
• Invalidate the basic axis compensation,
or command one axis at a time.