6. Axis Specifications Parameters
6.1 Axis Specifications Parameters
II - 98
#
Items
Details
Setting range (unit)
2019 revnum Return steps
Set up the steps required for reference point return
for each axis.
0: Does not execute reference point return.
1 to max. number of NC axes:
Sets up the steps required for reference point
return.
0 to max. number of
NC axes
2020 o
_
chkp
Spindle
orientation
completion
check during
second zero
point return
Set up the distance from the second zero point to the
position for checking that the spindle orientation has
completed during second zero point return. If the set
value is 0, the above check is omitted.
0 to 99999.999 (mm)
2021 out
_
f
Maximum
speed outside
soft limit range
Set up the maximum speed outside the soft limit
range.
0 to 999999
2022 G30SLX Validate soft
limit (automatic
and manual)
Set up this function to disable a soft limit check
during the second to the fourth zero point return in
both automatic and manual operation modes.
0: Enables soft limit check.
1: Disables soft limit check.
0/1
2023 ozfmin
Set up ATC
speed lower
limit
Set up the minimum speed outside the soft limit
range during the second to the fourth zero point
return in both automatic and manual operation
modes.
0 to 999999
2024 synerr
Allowable error Set up the following for the master axis: the
maximum synchronization error that is allowed to
check for synchronization errors
When 0 is set up, the error check is not carried out.
0 to 99999.999 (mm)
During spindle C axis
synchronization
control:
0 to 99999.999 (°)