6. Axis Specifications Parameters
6.2 Zero Point Return Parameters
II - 101
(SETUP PARAM 2. 4/8)
#
Items
Details
Setting range (unit)
2037
2038
2039
2040
G53ofs
#2
_
rfp
#3
_
rfp
#4
_
rfp
Reference
point #1 to #4
Set up the position of the first, second, third, and fourth
reference points from the zero point of the basic
mechanical coordinates.
Basic mechanical coordinates
M
Reference point #1
Reference point #2
Reference point #3
Reference point #4
±999999.999 (mm)