6. Axis Specifications Parameters
6.3 Absolute Position Parameters
II - 102
6.3 Absolute Position Parameters
(SETUP PARAM 2. 5/8)
#
Items
Details
Setting range (unit)
2049
(PR)
type Absolute
position
detection
method
Specify the absolute position zero point alignment
method.
0: Not absolute position detection
1: Stopper method (push with mechanical stopper)
2: Origin point alignment method (align with
marked point)
3: Dog-type (align with dog and proximity switch)
4: Reference point alignment method II (align to
alignment mark)
(Type that does not return grid after reference
alignment)
9: Simple absolute position
(Not absolute position detection‚ but the position
when the power is turned off is registered.)
Automatic initial setting is valid only when the stopper
method is selected.
0 to 9
2050 absdir
Base point
of Z
direction
Set the direction of the absolute position reference point
(grid point immediately before) seen from the machine
reference point for when using reference point
alignment.
0: Positive direction
1: Negative
direction
2051 check
Check
Set the tolerable range for the movement amount
(deviation amount) when the power is turned OFF.
0: Not checked
1 to 99999.999mm: If the difference of the position
when the power is turned OFF
and turned ON again is larger
than this value‚ an alarm will
be output.
0 to 99999.999 (mm)
2052 absg28
Not used.
2053 absm02
Not used.
2054 clpush
Current limit
(%)
Set up the current limit value for the initial setting when
detecting an absolute position with a dog-less system.
The setup value is the ratio of the current limit value to
the rated value.
0 to 100 (%)
2055 pushf
Push speed Set the feedrate for the automatic initial setting during
stopper method.
1 to 999 (mm/min)
2056 aproch
Approach
Set the approach distance for the automatic initial
setting in the push method.
Approach distance:
After using stopper once‚ the
tool returns this distance‚ and
then use stopper again.
When set to 0‚ the reference
point coordinates set in #2037
G53ofs will be used as the
approach start position.
0 to 999.999 (mm)