6. Axis Specifications Parameters
6.4 Axis Specifications Parameters 2
II - 104
6.4 Axis Specification Parameters 2
(SETUP PARAM 2. 6/8)
#
Items
Details
Setting range (unit)
2061 OT_1B- Soft limit IB- Set up the coordinates of the lower limit of the inhibited
area of stored stroke limit IB.
Specify a value in the basic mechanical coordinates
system. If the same value (non-zero) with the same
sign as that of #2062 OT_IB+ is specified, the stored
stroke limit IB function is disabled.
±99999.999 (mm)
2062 OT_1B
+
Soft limit IB+ Set up the coordinates of the upper limit of the inhibited
area of stored stroke limit IB.
Specify a value in the basic mechanical coordinates
system.
±99999.999 (mm)
2063 OT_1B
type
Soft limit IB
type
Select OT_IB or OT_IC in which OT_IB+/- is used in
stored stroke limit I.
0: Soft limit IB valid
1: Soft limit IB and IC invalid
2: Soft limit IC valid
3: When using the inclined axis specifications, the
soft limit is checked with the program coordinate
system.
Note: This is invalid for axes other than the
inclined axis' base axis and inclined
axis.
0/1/2/3
2064 rapid2
Speed 2
Specify the speed applicable to the speed area for
2-stage acceleration/deceleration. If the following
conditions are not satisfied, inclination constant
acceleration/deceleration is used for operation.
(0 < rapid2 < rapid and rapid3 = 0 and 0 < G0tL2 <G0tL
and G0tL3 = 0)
(Applicable only to M64 D version series)
Related parameters: #1223 aux07 bit 0 (Rapid
traverse content multistage
acceleration/deceleration)
#2065 G0tL2 (Time constant 2)
0 to 999999
(mm/min)
0: No setting
2065 G0tL2
Time
constant 2
Specify the time constant applicable to the speed area
for 2-stage acceleration/deceleration. If the following
conditions are not satisfied, inclination constant
acceleration/deceleration is used for operation.
(0 < rapid2 < rapid and rapid3 = 0 and 0 < G0tL2 <G0tL
and G0tL3 = 0)
(Applicable only to M64 D version series)
Related parameters: #1223 aux07 bit 0 (Rapid
traverse content multistage
acceleration/deceleration)
#2064 rapid2 (Speed 2)
1 to 4000 (ms)
0: No setting