6. Axis Specifications Parameters
6.4 Axis Specifications Parameters 2
II - 109
#
Items
Details
Setting range (unit)
2083 rot_2
Linear type
rotary axis II
The linear type rotary axis II is validated.
0: Invalidate linear type rotary axis II.
1: Validate linear type rotary axis II.
Note that this is valid only when the power is turned
ON, and the rotary axis parameters must be
validated.
The axis type is determined by the combination with
the existing rotary axis parameters (#1017 rot rotary
axis). If #1017 is set to 0, the linear axis will be
applied. When #1017 is set to 1 and this parameter
is set to 0, the rotary axis will be applied, and when
set to 1, the linear type rotary axis II will be applied.
<Related parameters>
#1089: Cut_RT Short cut for rotary axis
#1090: Lin_RT
Linear type rotary axis
#2070: div_RT
Rotary axis division count
#2076: index_x Index table indexing axis
Note: These parameters are invalid when the linear
type rotary axis II is set.
0/1
2084 G60_ax Unidirectional
positioning
operation
selection
Select the unidirectional positioning with G00.
Select the axis for carrying out the positioning per
time operation when the positioning command is
issued regardless of the unidirectional positioning
command and modal.
0: Carry out unidirectional positioning according
to the command and modal.
1: When the positioning command (G00) is
issued, carry out unidirectional positioning
regardless of the command and modal.
<Related parameters>
#8209 G60 SHIFT:
The final positioning direction and distance
for the unidirectional positioning command is
set for each axis.
#2076 Index table indexing axis:
Set the indexing axis for each axis.
0/1