6. Axis Specifications Parameters
6.4 Axis Specifications Parameters 2
II - 110
(SETUP PARAM 2. 8/8)
#
Items
Details
Setting range (unit)
2086 exdcax
External
deceleration
speed
Set the upper limit of the feedrate for each axis when
the external deceleration signal is valid.
This parameter is valid when the #1239 set11/bit6
external deceleration axis compliance valid is set to
1.
1 to 999999 (mm/min)
2087 syncnt
Synchroniza-
tion/super-
imposition
control setting
for each axis
Set the polarity of synchronous axis in respect to
basic axis to the bit corresponding to each axis.
0: Polarity with basic axis is positive
1: Polarity with basic axis is negative
0 to FF
(hexadecimal)
2088 bsax_sy Reference axis
for
synchronous
control
Set the basic axis for synchronous control with the
2nd axis name (axname2).
A numerical character cannot be set to the 1st
character.
Axis name
2089 bsax_pl Reference axis
for
superimposi-
tion control
Set the basic axis for superimposition control with
the 2nd axis name (axname2).
A numerical character cannot be set to the 1st
character.
Axis name
2090 plrapid
Rapid traverse
rate for super-
imposition
control
Set the rapid traverse rate for superimposition
control.
(Equivalent to #2001 rapid (rapid traverse rate).)
1 to 999999 (mm/min)
2091 plclamp Cutting feed
clamp speed
for super-
imposition
control
Set the cutting feed clamp speed for superimposition
control.
(Equivalent to #2002 clamp (cutting feed clamp
speed).)
1 to 999999 (mm/min)
2092 plG0tL
G0 time
constant for
superimposi-
tion control
(linear)
Set the G0 time constant (linear) for superimposition
control.
(Equivalent to #2004 G0tL (G0 time constant
(linear).)
1 to 4000 (ms)
2093 plG0t1
G0 time
constant for
superimposi-
tion control
(primary delay)
Set the G0 time constant (primary delay) for
superimposition control.
(Equivalent to #2005 G0t1 (G0 time constant
(primary delay).)
1 to 5000 (ms)
2094 plG1tL
G1 time
constant for
superimposi-
tion control
(linear)
Set the G1 time constant (linear) for superimposition
control.
(Equivalent to #2007 G1tL (G1 time constant
(linear).)
1 to 4000 (ms)