6. Axis Specifications Parameters
6.4 Axis Specifications Parameters 2
II - 111
#
Items
Details
Setting range (unit)
2095 plG1t1 G1 time
constant for
superimposi-
tion control
(primary
delay)
Set the G1 time constant (primary delay) for
superimposition control.
(Equivalent to #2008 G1t1 (G1 time constant (primary
delay).)
1 to 5000 (ms)
2096 crncsp Minimum
corner
deceleration
speed
Set the minimum clamp speed for corner deceleration
during the high-accuracy control mode. Normally set
"0".
Note: This parameter is invalid during SSS control.
0 to 1000000
(mm/min)
2099 igConr Axis excluded
from corner
angle
calculation
Set the axis excluded from the corner angle calculation.
For example, set this for the Cs axis during spring
machining.
0/1
2102 skip_tL Skip time
constant
linear
Set up a linear control time constant for variable speed
skip acceleration and deceleration.
The time constant is validated when LC (cutting feed
with linear acceleration and deceleration) or F
(acceleration and deceleration by software) is selected
in acceleration or deceleration mode "#2003 smgst".
1 to 4000 (ms)
2103 skip_t1 Skip time
constant
primary delay
acceleration
and
deceleration
by software
second stage
Set up a primary-delay time constant for variable speed
skip acceleration and deceleration.
The time constant is validated when C1 (cutting feed
with primary delay) or C3 (exponential acceleration and
linear deceleration) is selected in acceleration or
deceleration mode "#2003 smgst".
When acceleration or deceleration by software is
selected, the second-step time constant is used.
1 to 5000 (ms)