1. List of Alarms
1.1 Operation Alarms
I - 8
Error No.
Details
Remedy
1036
Synchronous control designation disable
The synchronous control operation
method selection (R435 register) was
set when the mode was not the C axis
mode.
The synchronous control operation
method selection (R435 register) was
set in the zero point not set state.
Mirror image disable state
The external mirror image or parameter
mirror image was commanded during
facing turret mirror image.
• Set the R435 register to 0.
• Check the program and parameters.
1037
Synchronous control was started or
canceled when synchronous control could
not be started or canceled.
• Check the program and parameters.
1038
A movement command was issued to a
synchronous axis in synchronous control.
• Check the program.
1043
No spindle speed clamp
The constant surface speed command
(G96) was issued to the spindle which is
not selected for the spindle speed clamp
command (G92/G50) under Multiple
spindle control II.
Press the reset key and carry out the
remedy below.
• Select the spindle before commanding
G92/G50.
(Applicable only to M65 V series and M64 C
version series)
1106
Spindle synchronous phase calculation
illegal
The spindle synchronization phase
alignment command was issued while
the spindle synchronization phase
calculation request signal was ON.
• Check the program.
• Check the sequence program.
(The bold characters are the messages displayed on the screen.)
M90 PARAM SET MODE
M90 Messages output when the setup parameter lock function
is enabled are displayed.
Error No.
Details
Remedy
—
Setup parameter lock released
The setup parameter lock is released.
Automatic start is disabled when setup
parameters can be set.
• Refer to the manual issued by the
machine manufacturer.