7. Servo Parameters
7.1 MDS-B-SVJ2
II - 125
No. Items
Details
Setting
range
2236
(PR)
SV036
PTYP
Regenera-
tive resistor
type
F E D C B A 9 8
amp rtyp
7 6 5 4 3 2 1 0
emgx
bit Explanation
0
1
2
3
Always set to "0(0000) ".
4
Set the external emergency stop function. (Setting is prohibited
for values with no description.)
5
Set-
ting
Explanation
6
0
External emergency stop invalid
7
emgx
4
External emergency stop valid
8
Set the regenerative resistor type.
9
Set-
ting
Explanation
A 0
Drive unit standard built-in resistor (SVJ2-01
doesn’t have a built-in resistor)
B
rtyp
1 Setting
prohibited
2
MR-RB032
3
MR-RB12 or GZG200W390HMK
4
MR-RB32 or GZG200W1200HMK: 3 units
connected in parallel
5
MR-RB30 or GZG200W390HMK: 3 units
connected in parallel
6
MR-RB50 or GZG300W390HMK: 3 units
connected in parallel
7 to F Setting prohibited
C
D
E
F
amp
Always set to "0(0000) ".