7. Servo Parameters
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
II - 147
No. Items
Details
Setting
range
2225
(PR)
SV025
MTYP
Motor
/Detector
type
F E D C B A 9 8
pen ent
7 6 5 4 3 2 1 0
mtyp
bit Explanation
0
Set the motor type.
1
Set this along with SV017 (SPEC)/spm.
2
1) When SV017/spm=0 (Normal drive unit)
3
Set-
ting
0x 1x
2x
3x 4x
5x
6x 7x
4
x0
HA40N
HA50L
HA53L
5
x1
HA80N
HA100L HA103L
6
x2
HA100N
HA200L HA203L
7
x3
HA200N
HA300L HA303L
x4
HA300N
HA500L HA503L
mtyp
x5
HA700N
x6
HA900N
x7
HA-LH11K2
x8
HA-LH15K2
x9
xA
HA150L HA153L
xB
xC
xD
HA-LF15K2
xE
xF
Set-
ting
8x 9x
Ax
Bx Cx Dx Ex Fx
x0 HA43N
HC52
HC53
x1 HA83N
HC102
HC103 HC103R
x2 HA103N
HC152
HC153 HC153R
x3 HA203N
HC202
HC203 HC203R
x4 HA303N
HC352
HC353 HC353R
x5 HA703N
HC452
HC453 HC503R
x6
HC702
HC703
x7
HC902
x8
x9
xA HA93N
xB
xC HA053N
xD HA13N
xE HA23N
xF HA33N