1. List of Alarms
1.2 Stop Codes
I - 12
T03 BLOCK STOP
This indicates that automatic operation stopped after executing
one block of the program.
Error No.
Details
Remedy
0301
SNGL BLK ON (Single block on)
The SINGLE BLOCK switch on the
machine operation panel is ON.
The single block or machine lock switch
changed.
• Automatic operation can be resumed by
turning the CYCLE START switch ON.
0302
User macro stop
The block stop command was issued in
the user macro program.
• Automatic operation can be resumed by
turning the CYCLE START switch ON.
0303
Mode change
The automatic mode changed to another
automatic mode.
• Return to the original automatic
operation mode‚ and resume automatic
operation by turning the CYCLE START
switch ON.
0304
MDI completion
The last block of MDI was completed.
• Set MDI again‚ and turn the CYCLE
START switch ON to resume MDl
operation.
0305
Block start interlock
The interlock signal that locks the block
start is entered.
• Check the sequence program.
0306
Block cutting start interlock
The interlock signal that locks the block
cutting start is entered.
• Check the sequence program.
0310
Offset change of inclined Z-axis during
program operation
Whether to validate the offset of the
inclined Z-axis switched during program
operation.
• Automatic operation can be restarted by
turning ON the cycle start switch.
T04 COLLATION STOP
Collation stop was applied during automatic operation.
Error No.
Details
Remedy
0401
Collation stop occurred.
• Automatic operation can be restarted
with automatic start.