1. List of Alarms
1.3 Servo spindle Alarms
I - 14
1.3 Servo/Spindle Alarms
This section describes alarms occurred by the errors in the servo system such as the drive unit‚ motor and
encoder, etc. The alarm message‚ alarm No. and axis name will display on the alarm message screen. The
axis where the alarm occurred and the alarm No. will also display on the servo monitor screen and the
spindle monitor screen respectively. If several alarms have occurred‚ up to two errors per axis will display
on the servo monitor screen and the spindle monitor screen respectively.
(The bold characters are the messages displayed on the screen.)
S
SERVO ALARM :
××
0
0
ΔΔ
Axis name
Alarm No.
Alarm reset class
Alarm class
Servo : Axis name
Spindle : “S”, “T”, “M”, “N”
(Note 1) The alarm class and alarm reset class combinations are preset.
(Refer to the separate table for S02, S51 and S52.)
Alarm class
Alarm reset class
Resetting methods
S01
PR
After removing the cause of the alarm, reset the
alarm by turning the NC power ON again.
S03
NR
After removing the cause of the alarm, reset the
alarm by inputting the NC RESET key.
S04
AR
After removing the cause of the alarm, reset the
alarm by turning the drive unit power ON again.
(Note 2) The resetting method may change according to the alarm class.
For example, even if “S03 SERVO ALARM: NR” is displayed, it may be necessary to turn the NC
power ON again.
Alarm No.
Name
Meaning
10
Insufficient voltage
Insufficient PN bus voltage was detected in main circuit.
11
Axis selection error
Setting of the axis No. selection switch is incorrect.
12
Memory error 1
A CPU error or an internal memory error was detected during the
power ON self-check.
13
Software processing
error 1
Software processing has not finished within the specified time.
14
Software processing
error 2
Software processing has not finished within the specified time.
15
Memory error 2
A CPU error or an internal memory error was detected during the
power ON self-check.
16
Magnetic pole
position detection
error
Initial magnetic pole for motor control has not been formed yet.
17
A/D converter error
An error was detected in the A/D converter for detecting current FB.
18
Motor side detector:
Initial
communication error
Initial communication with the motor end detector failed.
19
Detector
communication error
in synchronous
control
Initial communication with the motor end detector on master axis
failed when setting closed-loop current synchronous control. Or the
communication was interrupted.