7. Servo Parameters
7.4 Supplement
II - 201
(c) Setting the output scale
When "0" is set, the output will be made with the standard output unit. To change the output unit, set
a value other than "0".
The scale is set with a 1/256 unit. When 256 is set, the unit will be the same as the standard output.
# No.
Abbrev Parameter
name
2263
SV063
DA1MPY
D/A output channel 1
output scale
2264
SV064
DA2MPY
D/A output channel 2
output scale
(Example 1) When SV061 = 5, SV063 = 2560
The V-phase current value will be output with 1 A/V unit to D/A output ch.1.
(Example 2) When SV063 = 11, SV064 = 128
The position droop will be output with a 2mm/Vunit to D/A output ch.2.