8. MDS-B-SP/SPH, SPJ2 Spindle Parameters
8.1 MDS-B-SP/SPH, SPJ2 Spindle Base Specifications Parameters
II - 214
#
Items
Details
Setting range (Unit)
3060 sptc7 Spindle
synchroniza-
tion multi-step
acceleration/
deceleration
changeover speed 7
Set the spindle speed for changing the 7th
step's acceleration/deceleration time
constant.
0 to 99999 (r/min)
3061 spdiv1 Magnification for time
constant changeover
speed 1
Set the acceleration/deceleration time
constant between the spindle
synchronization multi-step
acceleration/deceleration changeover speed
1 (sptc1) to the spindle synchronization
multi-step acceleration/
deceleration changeover speed 2 (sptc2) as
a magnification in respect to the spindle
synchronization acceleration/deceleration
time constant (spt).
0 to 127
3062 spdiv2 Magnification for time
constant changeover
speed 2
Set the acceleration/deceleration time
constant between the spindle
synchronization multi-step
acceleration/deceleration changeover speed
2 (sptc2) to the spindle synchronization
multi-step acceleration/deceleration
changeover speed 3 (sptc3) as a
magnification in respect to the spindle
synchronization acceleration/deceleration
time constant (spt).
0 to 127
3063 spdiv3 Magnification for time
constant changeover
speed 3
Set the acceleration/deceleration time
constant between the spindle
synchronization multi-step
acceleration/deceleration changeover speed
3 (sptc3) to the spindle synchronization
multi-step acceleration/deceleration
changeover speed 4 (sptc4) as a
magnification in respect to the spindle
synchronization acceleration/deceleration
time constant (spt).
0 to 127
3064 spdiv4 Magnification for time
constant changeover
speed 4
Set the acceleration/deceleration time
constant between the spindle
synchronization multi-step
acceleration/deceleration changeover speed
4 (sptc4) to the spindle synchronization
multi-step acceleration/deceleration
changeover speed 5 (sptc5) as a
magnification in respect to the spindle
synchronization acceleration/deceleration
time constant (spt).
0 to 127
3065 spdiv5 Magnification for time
constant changeover
speed 5
Set the acceleration/deceleration time
constant between the spindle
synchronization multi-step
acceleration/deceleration changeover speed
5 (sptc5) to the spindle synchronization
multi-step acceleration/deceleration
changeover speed 6 (sptc6) as a
magnification in respect to the spindle
synchronization acceleration/deceleration
time constant (spt).
0 to 127