8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 218
No. Items
Details
Setting
range
Standard
setting
3233
(PR)
SP033 SFNC1 Spindle
function 1
Set the spindle function 1 in bit units.
0000 to
FFFF
HEX setting
0000
3234
(PR)
SP034 SFNC2 Spindle
function 2
Set the spindle function 2 in bit units.
(Note1)
To validate bit3(mkc2), NC side needs to
prepare.
(Note1)
Always turn the bit2 at the same time to use
bit3.
0000 to
FFFF
HEX setting
0000
F E D
C
B A 9 8
poff
hzs
ront
7 6 5 4 3 2 1 0
sftk
dflt 1a2m
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
1a2m
1 amplifier
2 motor function: Invalid
1 amplifier
2 motor function: Valid
1
dflt
Default motor: Main
Default motor: Sub
2
sftk
SF-TK card invalid
SF-TK card valid
3
4
5
6
7
8
9
A
B
C ront
D
E hzs
F poff
This is a fixed control bit.
F E D
C
B A 9 8
7 6 5 4 3 2 1 0
mts1
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
mts1
Special motor constant
invalid
Special motor constant
setting valid
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F