8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 220
No. Items
Details
Setting
range
Standard
setting
3237
(PR)
SP037 SFNC5 Spindle
function 5
Set the spindle function 5 in bit units.
0000 to
FFFF
HEX setting
0000
3238
(PR)
SP038 SFNC6 Spindle
function 6
Set the spindle function 6 in bit units.
(Note)
Always set "0" for the empty bits.
0000 to
FFFF
HEX setting
0000
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
enco
Encoder orientation
invalid
Encoder orientation
valid
1
2
plgo
PLG orientation invalid
PLG orientation valid
3
4
5
6
7
8
nstv
No-signal detection type
(Always monitoring)
Monitoring only in
position loop or
orientation-mode
9
A
B
C
D
E
F
F E D
C
B A 9 8
nstv
7 6 5 4 3 2 1 0
plgo
enco
F E D
C
B A 9 8
oplp
7 6 5 4 3 2 1 0
pftm
alty
bit Name Meaning when set to 0 Meaning when set to 1
0
alty
Deceleration stop during
special alarm invalid
Deceleration stop during
special alarm valid
1
2
pftm
Thread cutting position
data invalid
Thread cutting position
data valid
3
4
5
6
7
8
9
A
B
C
D
E
F
oplp
Open loop operation
invalid
Open loop operation
valid