8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 221
No. Items
Details
Setting
range
Standard
setting
3239
(PR)
SP039 ATYP Amplifier
type
Set the amplifier type.
Set each amplifier type or "0".
This parameter corresponds to MDS-B-SPJ2.
0000 to
FFFF
HEX
setting
0000
3240
(PR)
SP040 MTYP Motor type
0000 to
FFFF
HEX
setting
0000
This is valid when SP034 (SFNC2) bit 0 is set
to 0.
Refer to the following standard motors, and set
the applicable motor number.
Parameter setting
Amplifier type
0000
--
0001
SPJ2-02
0002
SPJ2-04
0003
SPJ2-075
0004
SPJ2-15
0005
SPJ2-22
0006
SPJ2-37
0007
SPJ2-55
0008
SPJ2-75
0009
SPJ2-110/110C
Paramete
r setting
Motor type
Maximum
speed
Corresponding
amplifier
1000
1001 SJ-P0.2A
10000
r/min SPJ2-02
1002 SJ-P0.4A
10000
r/min SPJ2-04
1003 SJ-P0.75A 10000
r/min SPJ2-075
1004 SJ-P1.5A
10000
r/min SPJ2-15
1005 SJ-P2.2A
8000
r/min SPJ2-22
1006 SJ-P3.7A
8000
r/min SPJ2-37
1007 SJ-PF5.5-01 8000
r/min SPJ2-55
1008 SJ-PF7.5-01 8000
r/min SPJ2-75
1009 SJ-PF11-01 6000
r/min SPJ2-110/110C