8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 230
No. Items
Details
Setting
range
Standard
setting
3382
(PR)
SP182 VCSS
Change
starting speed
of variable
speed loop
proportional
gain at
spindle
synchroniza-
tion
Set the speed for starting change of speed
loop proportional gain at spindle
synchronization.
SP182
SP017
SP178
SP178×
(SP181/100)
Proportional gain
Speed
0 to 32767
(r/min)
0
3383 SP183 SYNV
Sync match-
ing speed at
spindle syn-
chronization
For changeover from the speed loop to the
position loop at spindle synchronization, set
a speed command error range for output of
the sync speed matching signal.
0 to 1000
(r/min)
20
3384
(PR)
SP184 FFCS
Acceleration
rate feed
forward gain
at spindle
synchroniza-
tion
Set the acceleration rate feed forward gain
at spindle synchronization.
This parameter is used only with the SPJ2.
0 to 1000
(%)
0
3385 SP185 SINP
Spindle sync
in-position
width
Set the position error range for output of the
in-position signal at spindle
synchronization.
1 to 2880
(1/16°)
16
3386
(PR)
SP186 SODR
Excessive
error width at
spindle
synchroniza-
tion
Set the excessive error width at spindle
synchronization.
1 to 32767
(1/4 pulse)
(1 pulse
=0.088°)
32767
3387
(PR)
SP187 IQGS
Current loop
gain magnifi-
cation1 at
spindle syn-
chronization
Set the magnification of current loop gain
(torque component) at spindle
synchronization.
1 to 1000
(%)
100
3388
(PR)
SP188 IDGS
Current loop
gain magnifi-
cation 2 at
spindle syn-
chronization
Set the magnification of current loop gain
(excitation component) at spindle
synchronization.
1 to 1000
(%)
100
3389
to
3392
SP189
to
SP192
Not used. Set to "0".