8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 240
No. Items
Details
Setting
range
Standard
setting
3234
(PR)
SP034 SFNC2 Spindle
function 2
Set the spindle function 2 in bit units.
0000 to
FFFF
HEX setting
000C
3235
(PR)
SP035 SFNC3 Spindle
function 3
Set the spindle function 3 in bit units.
0000 to
FFFF
HEX setting
0000
F E D
C
B A 9 8
7 6 5 4 3 2 1 0
mkc2 mkch invm mts1
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
mts1
Special motor constant
invalid
Special motor constant
setting valid
1
invm
A general-purpose
motor FV control invalid
A general-purpose
motor FV control valid
2
mkch
Coil switch function
invalid
Coil switch function valid
3
mkc2
Coil switch specification
2 invalid
Coil switch specification
2 valid (Note1) (Note2)
4
5
6
7
8
9
A
B
C
D
E
F
(Note1)
To validate bit3(mkc2), NC side needs to prepare.
(Note2)
Always turn the bit2 at the same time to use bit3.
F E D
C
B A 9 8
7 6 5 4 3 2 1 0
lbsd hbsd lwid hwid
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
hwid
H-coil wide-range
constant output invalid
H-coil wide-range
constant output valid
1
lwid
L-coil wide-range
constant output invalid
L-coil wide-range
constant output valid
2
hbsd
H-coil base slide invalid
H-coil base slide valid
3
lbsd
L-coil base slide invalid
L-coil base slide valid
4
5
6
7
8
9
A
B
C
D
E
F
(Used with SPJ.)