8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 248
No. Items
Details
Setting
range
Standard
setting
3263
(PR)
SP063 OLT
Overload
alarm
detection time
Set the time constant for detection of the
motor overload alarm.
0 to 1000
(s)
60
3264
(PR)
SP064 OLL
Overload alarm
detection level
Set the detection level of the motor overload
alarm.
0 to 120
(%)
110
3265
(PR)
SP065 VCGN1 Target value of
variable speed
loop
proportional
gain
Set the magnification of speed loop
proportional gain with respect to SP022
(VGNP1) at the maximum motor speed
defined in SP017 (TSP).
0 to 100
(%)
100
3266
(PR)
SP066 VCSN1 Change
starting speed
of variable
speed loop
proportional
gain
Set the speed when the speed loop
proportional gain change starts.
SP066
SP017
SP022
SP022×
(SP065/100)
Proportional gain
Speed
0 to 32767
(r/min)
0
3267
(PR)
SP067 VIGWA Change
starting speed
of variable
current loop
gain
Set the speed where the current loop gain
change starts.
0 to 32767
(r/min)
0
3268
(PR)
SP068 VIGWB Change
ending speed
of variable
current loop
gain
Set the speed where the current loop gain
change ends.
0 to 32767
(r/min)
0
3269
(PR)
SP069 VIGN
Target value of
variable
current loop
gain
Set the magnification of current loop gain
(torque component and excitation
component) for a change ending speed
defined in SP068 (VIGWB).
When this parameter is set to "0", the
magnification is 1.
SP067
SP017
SP068
Speed
1-fold
SP069×(1/16)-fold
0 to 32767
(1/16-fold)
0
SP017 (TSP)
Maximum
motor speed
SP067
(VIGWA)
SP068
(VIGWB)
SP069
(VIGN)
0 to 6000
0
0
0
6001 to 8000
5000
8000
45
8001 or more
5000
10000
64