8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 249
No. Items
Details
Setting
range
Standard
setting
3270 SP070 FHz
Machine
resonance
suppressio
n filter
frequency
When machine vibration occurs in speed and
position control, set the frequency of the
required vibration suppression.
Note that a value of 100Hz or more is set.
Set to "0" when not used.
0 to 3000
(Hz)
0
3271
(PR)
SP071 VR2WA
3272
(PR)
SP072 VR2WB
3273
(PR)
SP073 VR2GN
3274
(PR)
SP074 IGDEC
Fixed
control
constant
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0
3275 SP075 R2KWS
3276 SP076
FONS
Machine
resonance
suppressio
n filter
operation
speed
When the vibration increases in motor stop
(ex. in orientation stop) when the machine
vibration suppression filter is operated by
SP070, operate the machine vibration
suppression filter at a speed of this parameter
or more.
When set to "0", this is validated for all speeds.
0 to 32767
(r/min)
0
3277
(PR)
SP077 TDSL
Fixed
control
constant
Set by Mitsubishi.
Set "14" unless designated in particular.
14
3278
(PR)
SP078 FPWM
3279
(PR)
SP079 ILMT
Fixed
control
constant
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0
F E D
C
B A 9 8
r2ini
7 6 5 4 3 2 1 0
r2am r2lm r2dn no51 r2ch
bit
Name
Meaning when set to 0
Meaning when set to 1
0 r2ch
1 no51
2 r2dm
3 r2lm
4 r2am
This is used by Mitsubishi.
Set to "0" unless particularly designated.
5
6
7
8
r2ini
This is used by Mitsubishi.
Set to "0" unless particularly designated
9
A
B
C
D
E
F
Summary of Contents for MELDAS 60 Series