8. Spindle Parameters
8.4 MDS-C1-SPM
II - 272
No. Items
Details
Setting
range
Standard
setting
3234
(PR)
SP034 SFNC2 Spindle
function 2
Set the spindle function 2 in bit units.
0000 to
FFFF
HEX
setting
000C
F E D
C
B A 9 8
7 6 5 4 3 2 1 0
mkc2 mkch Mk3c mts1
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
mts1
Special motor constant
invalid
Special motor constant
setting valid
1
Mk3c
3-step coil changeover
function invalid
3-step coil changeover
function valid
2
mkch
Coil switch function
invalid
Coil switch function valid
3
mkc2
Coil switch specification
2 invalid
Coil switch specification
2 valid (Note1) (Note2)
4
5
6
7
8
9
A
B
C
D
E
F
(Note1)
To validate bit3(mkc2), NC side needs to prepare.
(Note2)
Always turn the bit2 at the same time to use bit3.