8. Spindle Parameters
8.4 MDS-C1-SPM
II - 274
No. Items
Details
Setting
range
Standard
setting
3236
SP036
Not used. Set to "0".
3237
(PR)
SP037 SFNC5 Spindle
function 5
Set the spindle function 5 in bit units.
0000 to
FFFF
HEX
setting
0000
F E D
C
B A 9 8
nsno nosg
7 6 5 4 3 2 1 0
plgo
enco
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
enco
Encoder orientation
invalid
Encoder orientation
valid
1
2
plgo
PLG orientation invalid
PLG orientation valid
3
4
5
6
7
8
nosg
No-signal detection type
(Always monitoring)
Monitoring only in
position loop or
orientation-mode
9 nsno
No-signal detection
valid
No-signal detection
invalid
A
B
C
D
E
F
(Note)
For bit0 to 2, do not set two bits or more to
"1" at the same time.