8. Spindle Parameters
8.4 MDS-C1-SPM
II - 275
No. Items
Details
Setting
range
Standard
setting
3238
(PR)
SP038 SFNC6 Spindle
function 6
Set the spindle function 6 in bit units.
0000 to
FFFF
HEX
setting
0000
F E D
C
B A 9 8
XFzs
pl80 sdt2
7 6 5 4 3 2 1 0
hzrn orm
tdn
plg2 pftm
alty
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
alty
Deceleration stop during
special alarm invalid
Deceleration stop during
special alarm valid
1
2
pftm
Encoder feedback serial
communication invalid
Encoder feedback serial
communication valid
3
plg2
Semi-closed pulse
output signal ×2 invalid
Semi-closed pulse
output signal ×2 valid
4
tdn
Fixed control bit
5
6
orm
Orientation start memo
invalid
Orientation start memo
valid
7 hzrn
8 sdt2
9 pl80
Fixed control bit
A
B
C
XFzs
Fixed control bit
D
E
F