8. Spindle Parameters
8.4 MDS-C1-SPM
II - 277
No. Items
Details
Setting
range
Standard
setting
3241
(PR)
SP041 PTYP
Power supply
type
Power supply type
0000 to
FFFF
HEX
setting
0000
3242
(PR)
SP042 CRNG C-axis detector
range
This parameter is used to set the C-axis
detector range.
Set "0" for this parameter.
"2" is used by Mitsubishi for testing.
0 to 7
0
F E D
C
B A 9 8
amp rtyp
7 6 5 4 3 2 1 0
ptyp
bit
Explanation
0
1
2
When the CN4 connector of the drive unit and the power supply are
connected, setting below is necessary.
To validate the external emergency stop function, add 40h.
3
Set-
ting
0x 1x 2x 3x 4x 5x
6x 7x
8x
4
x0
Not
used
CV-300
5
x1
CV-110
CR-10
6
x2
CV-220
CR-15
7
ptyp
x3
CR-22
x4 CV-37
CR-37
x5
CV-150
CV-450
CV-550
x6 CV-55
CV-260
CR-55
x7
CV-370
x8 CV-75
CR-75
x9
CV-185
CR-90
8
Set the regenerative resistor type when MDS-A-CR is used.
9
Set-
ting
Regenerative resistor
model name
Resistance
value
Capacity
A
0
MDS-C1-CV (Setting when using power supply regeneration)
B
rtyp
1 GZG200W260HMJ
26
Ω
80W
2
GZG300W130HMJ
×
2 26
Ω
150W
3
MR-RB30
13
Ω
300W
4
MR-RB50
13
Ω
500W
5
GZG200W200HMJ
×
3 6.7
Ω
350W
6
GZG300W200HMJ
×
3 6.7
Ω
500W
7
R-UNIT-1
30
Ω
700W
8
R-UNIT-2
15
Ω
700W
9
R-UNIT-3
15
Ω
2100W
A to D
No setting
E
Large ca ready ON high-speed sequence
F
Ready ON high-speed sequence
C
D
E
F
amp
Always set to “0”.