8. Spindle Parameters
8.4 MDS-C1-SPM
II - 278
No. Items
Details
Setting
range
Standard
setting
3243
(PR)
SP043 TRNG Synchronous
tapping, spindle
synchronous
detector range
This parameter is used to set the
synchronous tapping or spindle synchronous
detector range.
Set "0" for this parameter.
0 to 7
0
3244
(PR)
SP044 TRAN
S
NC communi-
cation
frequency
Set a frequency of data communication with
NC.
0 to 32767 Standard:
0
Special:
1028
3245 SP045 CSNT Dual
cushion
timer
Set the cycle to add the increment values in
the dual cushion process.
When this setting value is increased, the dual
cushion will increase, and the changes in the
speed during acceleration/deceleration will
become gradual.
0 to 1000
(ms)
0
3246
(PR)
SP046 CSN2 Speed
command dual
cushion
For an acceleration/deceleration time
constant defined in SP019 (CSN1) , this
parameter is used to provide smooth
movement only at the start of
acceleration/deceleration.
As the value of this parameter is smaller, it
moves smoother but the
acceleration/deceleration time becomes
longer.
To make this parameter invalid, set "0".
0 to 1000 0
3247
(PR)
SP047 SDTR Speed
detection reset
value
Set the reset hysteresis width for a speed
detection set value defined in SP020 (SDTS).
0 to 1000
(r/min)
30
3248
(PR)
SP048 SUT
Speed reach
range
Set the speed deviation rate with respect to
the commanded speed for output of the
speed reach signal.
0 to 100
(%)
15
3249 SP049 TLM2
Torque limit 2
Set the torque limit rate for the torque limit
signal 010.
1 to 120
(%)
20
3250 SP050 TLM3 Torque limit 3
Set the torque limit rate for the torque limit
signal 011.
1 to 120
(%)
30
3251 SP051 TLM4 Torque limit 4
Set the torque limit rate for the torque limit
signal 100.
1 to 120
(%)
40
3252 SP052 TLM5 Torque limit 5
Set the torque limit rate for the torque limit
signal 101.
1 to 120
(%)
50
3253 SP053 TLM6 Torque limit 6
Set the torque limit rate for the torque limit
signal 110.
1 to 120
(%)
60
3254 SP054 TLM7 Torque limit 7
Set the torque limit rate for the torque limit
signal 111.
1 to 120
(%)
70
3255
(PR)
SP055 SETM Excessive
speed deviation
timer
Set the timer value until the excessive speed
deviation alarm is output.
The value of this parameter should be longer
than the acceleration/deceleration time.
0 to 60 (s) 12