8. Spindle Parameters
8.4 MDS-C1-SPM
II - 283
No. Items
Details
Setting
range
Standard
setting
3298
(PR)
SP098 VGOP Speed loop
gain propor-
tional term in
orientation
mode
Set the speed loop proportional gain in
orientation mode.
When the gain is increased, rigidity is
improved in the orientation stop but
vibration and sound become larger.
0 to 2000
(1/s)
63
3299
(PR)
SP099 VGOI Orientation
mode speed
loop gain
integral term
Set the speed loop integral gain in
orientation mode.
0 to 2000
(0.1 1/s)
60
3300
(PR)
SP100 VGOD Orientation
mode speed
loop gain delay
advance term
Set a loop gain delay advance gain in
orientation mode.
When this parameter is set to "0", PI control
is applied.
0 to 1000
(0.1 1/s)
15
3301
(PR)
SP101 DINP Orientation
advance
in-position
width
When using the orientation in-position
advance function, set the in-position width
that is larger than the normal in-position
width defined in SP004 (OINP).
1 to 2880
(1/16°)
16
3302
(PR)
SP102 OODR Excessive error
value in
orientation
mode
Set the excessive error width in orientation
mode.
0 to 32767
(1/4 pulse)
(1 pulse=
0.088°)
32767
3303
(PR)
SP103 FTM
Index
positioning
completion
OFF time timer
Set the time for forcedly turn OFF the index
positioning completion signal (different from
the orientation completion signal) after the
leading edge of the indexing start signal.
0 to 10000
(ms)
200
3304
(PR)
SP104 TLOR Torque limit
value for
orientation
servo locking
Set the torque limit value for orientation
in-position output.
If the external torque limit signal is input, the
torque limit value set by this parameter is
made invalid.
0 to 120
(%)
100
3305
(PR)
SP105 IQG0 Current loop
gain magnifica-
tion 1 in
orientation
mode
Set the magnification for current loop gain
(torque component) at orientation
completion.
1 to 1000
(%)
100
3306
(PR)
SP106 IDG0 Current loop
gain magnifica-
tion 2 in
orientation
mode
Set the magnification for current loop gain
(excitation component) at orientation
completion.
1 to 1000
(%)
100
3307 SP107
CSP2 Deceleration
rate 2 in
orientation
mode
Set the deceleration rate in orientation
mode corresponding to the gear 001.
When this parameter is set to "0", same as
SP006 (CSP).
0 to 1000
0
3308 SP108
CSP3 Deceleration
rate 3 in
orientation
mode
Set the deceleration rate in orientation
mode corresponding to the gear 010.
When this parameter is set to "0", same as
SP006 (CSP).
0 to 1000
0